Centrifugal pumps performance test

 

Our highly reliable test open/closed circuits are capable for performing several kinds of dynamics centrifugal pumps performance tests as per the requirements of API 610.

Shop electro motors of up to 4 MW, auxiliary lubrication oil systems, auxiliary seal supply systems, as per the requirements of API 682 and bearing housing cooling systems are available to furnish the performance test most similar to the job situation.

Modern measuring and calibrating facilities are employed to yield the pumps characteristics data (pressure, brake horse power, etc.), bearing temperature, noise levels, package vibration (including FFT diagrams), etc. in different flow-rates.

Post-processing services in order to convert the shop results to the job situation, including the fluid density and viscosity effects, and/or mechanical effects, e.g. rpm, are offered. The results are judged against the acceptance criteria of the relevant code/standard.