Centrifugal pumps mechanical running test

 

Our highly reliable test open/closed circuits are capable for performing several kinds of dynamics centrifugal pumps mechanical running tests as per the requirements of API 610.

The running test needs to be performed with job motors and auxiliaries and we are able to furnish suitable baseplate, level screws, shims, bolting facilities, etc. Modern measuring and calibrating facilities are employed to yield the vibrations of the pump casing, bearing housing and electro motor.

We have made a new in-house leakage detector to detect any leakage from mechanical seal stuffing box, casing drains and suction/discharge flanges. The results are judged against the acceptance criteria of the relevant code/standard.